A vulnerability, which was classified as very critical, was found in FFmpeg up to 0.4.9 Pre1. Affected is the function str_read_packet. The manipulation leads to memory corruption.
This vulnerability is traded as CVE-2008-3162. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, has been found in PHP up to 7.0.0. This issue affects the function zend_throw_or_error of the file Zend/zend_execute_API.c. The manipulation leads to format string.
The identification of this vulnerability is CVE-2015-8617. The attack may be initiated remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical has been found in MyBB up to 1.8.25. Affected is an unknown function of the component Theme XML File Handler. The manipulation leads to sql injection.
This vulnerability is traded as CVE-2021-27890. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical has been found in Computalynx CProxy Server 3.3. This affects an unknown part of the component HTTP Request Handler. The manipulation leads to memory corruption.
This vulnerability is uniquely identified as CVE-2000-0395. It is possible to initiate the attack remotely. Furthermore, there is an exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as problematic, was found in Easy Digital Downloads Plugin up to 3.3.2 on WordPress. Affected is an unknown function of the component File Handler. The manipulation leads to information disclosure.
This vulnerability is traded as CVE-2024-12875. It is possible to launch the attack remotely. There is no exploit available.
A vulnerability was found in Bajie Java HTTP Server up to 0.95zxv4. It has been declared as problematic. This vulnerability affects unknown code of the component HTTP Server. The manipulation of the argument guestName/custMsg/cookiename leads to cross site scripting.
This vulnerability was named CVE-2003-1511. The attack can be initiated remotely. Furthermore, there is an exploit available.
A vulnerability was found in PyScript up to 2022-05-04. It has been rated as problematic. Affected by this issue is some unknown functionality of the component pyscriptjs. The manipulation leads to source code.
This vulnerability is handled as CVE-2022-30286. The attack may be launched remotely. Furthermore, there is an exploit available.
A vulnerability was found in Maianscriptworld Maian Cart 3.8. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Elfinder Plugin. The manipulation leads to improper access controls.
This vulnerability is known as CVE-2021-32172. The attack can be launched remotely. Furthermore, there is an exploit available.
A vulnerability, which was classified as problematic, was found in Annuairephp Annuaire PHP. This affects an unknown part. The manipulation of the argument nom leads to cross site scripting.
This vulnerability is uniquely identified as CVE-2012-0899. It is possible to initiate the attack remotely. Furthermore, there is an exploit available.
A vulnerability has been found in Infoproject Biznis Heroj and classified as critical. This vulnerability affects unknown code of the file login.php. The manipulation of the argument fin_nalog_id leads to sql injection.
This vulnerability was named CVE-2011-5039. The attack can be initiated remotely. Furthermore, there is an exploit available.
A vulnerability was found in Linux Kernel up to 2.6.14.1. It has been declared as problematic. Affected by this vulnerability is an unknown functionality of the file sysctl.c. The manipulation leads to improper resource management.
This vulnerability is known as CVE-2005-2709. The attack needs to be done within the local network. Furthermore, there is an exploit available.