A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow.
This vulnerability is traded as CVE-2024-2987. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Siemens SIMATIC PCS, SIMATIC WinCC Runtime Professional and SIMATIC WinCC up to 9.1. It has been classified as critical. Affected is an unknown function of the component Login Dialog Box. The manipulation leads to buffer overflow.
This vulnerability is traded as CVE-2023-50821. An attack has to be approached locally. There is no exploit available.
It is recommended to apply a patch to fix this issue.
A vulnerability classified as critical was found in Linux Kernel up to 5.15.4. Affected by this vulnerability is the function cs_desc of the component ALSA. The manipulation leads to null pointer dereference.
This vulnerability is known as CVE-2021-47211. The attack needs to be initiated within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, was found in Linux Kernel up to 4.19.217/5.4.161/5.10.81/5.15.4. Affected is the function set_hv_tscchange_cb of the component hyperv. The manipulation leads to null pointer dereference.
This vulnerability is traded as CVE-2021-47217. The attack can only be done within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability has been found in Linux Kernel up to 5.10.81/5.15.4 and classified as critical. Affected by this vulnerability is the function hashtab_init of the component SELinux. The manipulation leads to null pointer dereference.
This vulnerability is known as CVE-2021-47218. The attack can only be initiated within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Linux Kernel up to 5.4.209/5.10.80/5.14.20/5.15.3 and classified as critical. This issue affects the function of_parse_thermal_zones of the component thermal. The manipulation leads to null pointer dereference.
The identification of this vulnerability is CVE-2021-47202. The attack can only be initiated within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability was found in Linux Kernel up to 5.4.161/5.10.81/5.15.4. It has been declared as problematic. Affected by this vulnerability is the function free_netdev of the component dpaa2-eth. The manipulation leads to use after free.
This vulnerability is known as CVE-2021-47204. The attack needs to be initiated within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability has been found in Linux Kernel up to 5.10.88/5.15.11 and classified as critical. This vulnerability affects the function platform_device_put of the component intel_pmc_core. The manipulation leads to memory leak.
This vulnerability was named CVE-2021-47093. Access to the local network is required for this attack. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability classified as critical was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow.
This vulnerability is known as CVE-2024-2490. The attack can be launched remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as problematic has been found in Linux Kernel up to 5.12.9. Affected is the function io_link_timeout_fn of the component io_uring. The manipulation leads to use after free.
This vulnerability is traded as CVE-2021-47123. The attack needs to be done within the local network. There is no exploit available.
It is recommended to upgrade the affected component.
A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow.
The identification of this vulnerability is CVE-2024-2980. The attack may be initiated remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow.
This vulnerability is traded as CVE-2024-2981. It is possible to launch the attack remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection.
This vulnerability is known as CVE-2024-2982. Access to the local network is required for this attack. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow.
This vulnerability is handled as CVE-2024-2983. The attack may be launched remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow.
This vulnerability is uniquely identified as CVE-2024-2984. It is possible to initiate the attack remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow.
This vulnerability was named CVE-2024-2985. The attack can be initiated remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow.
The identification of this vulnerability is CVE-2024-2986. The attack may be initiated remotely. Furthermore, there is an exploit available.
The vendor was contacted early about this disclosure but did not respond in any way.
The vendor was contacted early about this disclosure but did not respond in any way.